PVC Waste Water Pipes
PVC waste water pipes inside and outside the building are used for pipes laid to drain the water. PVC waste water pipes EN 1326-1 standards DIN 19 531 due to the smooth inner and outer surfaces that do not allow the formation of deposits, bacteria produce odor making PVC waste water pipes, it is used in terms of ecological, economical ideal and for safety. Rigid PVC waste water pipes and fittings made of PVC material is resistant to different weather conditions. Fireproof, PVC waste water pipes it is the most preferred type of pipe construction sector thanks to its highly resistant and rigid structure.
Physical Properties of PVC Fittings
1) Vicat Softening Temperature (min 79ºC) (EN 727)
2) Influence of temperature (150 ° C – 30 minutes)
a) PVC waste water pipes the injection point around a radius of 15 times the thickness of the gap in the area, depth of the peeling or bubbles should not be more than 50% of the wall thickness at that point.
b) PVC waste water pipes Ring length of the cracks of the housing wall thickness in a distance 10 times, should be no more than 50% of the wall thickness at that point.
c) PVC waste water pipes opening in the connecting line should not exceed 50% of the thickness of the line.
d) PVC waste water pipes 30% of the meat depth of peelings in any other area of the part thickness, while the height of the wall thickness
It should not exceed 10%.
Value Standard Features
Specifications | Value | Standard |
Density | 1.41 | ISO 1183 |
WATER INTAKE 24 saat (%) | 0.05 | ASTM D570 |
WATER INTAKE, N/mm2 | 52 | ASTM D638 |
Bending strength, N / mm2 | 88 | ASTM D790 |
Modulus of elasticity N / mm2 | 3316 | ASTM D790 |
Hardness, (Rockwell R) | 115 | ASTM D785 |
IZOD notched impact (Joule) | 5.40 | ASTM D256 |
THERMAL LINEAR EXPANSION FACTOR, mm/mK | 0,06 | ASTM D696 |
Thermal conductivity, W / mK | 0,15 | ASTM D696 |
Vicat Softening Temperature (° C) | 93 | ASTM D1525 |
SURFACE RESISTANCE (OHM) | >1012 | ASTM D257 |
PVC Waste Water Pipes Uses
Groundwater and surface water transport system in place (city, industrial areas, waste water systems)
– The electricity and communication systems,
– Drainage, sewage and waste discharge systems
– Chemical and industrial plants are PVC waste water pipes used in pressurized lines.
Advantages of PVC Waste Water Pipes
– PVC waste water pipes Transport and installation because it is lightweight and easy to use.
– PVC sewage pipes and fittings, non-flammable and non-flammable.
– PVC waste water pipes Rust does not contaminate the rainwater.
Long lasting and maintenance-free.
– PVC waste water pipes decay and corrosion resistant, leakproof.
– PVC waste water pipes pressure loss is low.
– PVC waste water pipes the surface is smooth and shiny.
– PVC waste water pipes there -high impact strength.
– PVC waste water pipes pressurized Additional parts are fully compatible.
– PVC waste water pipes broken Not provide impact resistance as determined by the standard by more than 400%.
-It shows high resistance to chemical inputs.
-It Provides comfort by generating less noise.
It does not react with the mineral diameter shrinks.
Below -0 ° C, ice crack elastic structure.
PVC Material and Features
More than 50% of the product produced by PVC raw materials are used in the building industry in the world. PVC raw materials through environmentally friendly feature that does not appear to breaking events. PVC raw material is also used in PVC waste water pipes water color, smell and taste does not change, it does not harm human health. In the absence of filler material retains its original state. In fluid flows, especially in the vertical line it does not produce high levels of sound like the rigid pipes.
PVC raw materials is a raw material that is white has many positive features, historical development and many other details can be found PVC Pressurized Water Pipes page. PVC-U pipes and fittings produced in BD application class thickness (B and BD mark) is used for the following purposes;
– Hot and cold domestic wastewater
– Ventilation systems for domestic wastewater lines,
– Building rainwater supplies;
What is the difference in waste water and pressure systems between PP and PVC?
The main difference between PVC and PP; Hardness is the subject. PVC pipes superior in terms of hardness, which is more resistant than PP material in underground applications.
But PVC PP in accordance temperature impact strength and also lower.
In terms of flammability PP pipes in PVC pipe while burning flame burning as would be in the form of soot formation
PVC Waste Water Pipes Are Fireproof
DIN 4102 PVC waste water pipes have flammable UL94 standard produced by American standards, produced from hard PVC raw materials are defined as V-0.
Length and diameter of PVC WASTE WATER PIPES
PVC Waste Water Pipes Laying Rules
- PVC waste water pipes carefully laying the pipeline have started laying pipe life and improves quality. This is the base of the trench dug before the pipe laying operation must therefore be considered to be flat and stone free.
- PVC waste water pipes before laying the pipes filling quantity type of soil, depending on the season and climate should be between 1-1.5 meters.
- base will be poured into the ditch should be placed near the bed with 15 cm of sand and can be hard to stop the pipe.
- Check made the testing process which will be installed to seal the seams.
- PVC waste water pipes and fittings in muff bed, a damaged condition must be determined in the case of extreme and should not be used.
- PVC waste water pipes and fittings will be made in each assembly should be applied to the ends of liquid soap for an easy installation.
- Any iron clamps should be used except in PVC waste water pipes, steel etc. should not be material.
- After closing the floor if it is performed with the top of the PVC waste water pipes should be laid on top of her sand off the ground.
- In winter the pipes and fittings should be avoided, especially from shock. PVC waste water pipe trenches and filling status.